Do pressure regulators restrict the mass flow rate?

Engineering Asked by Izak the coder on August 7, 2020

Suppose we have a tank containing compressed air. If a hole is made in the tank the air will start flowing out. The mass flow rate of exiting air will be heavily dependent on the diameter of the orifice (ie the narrowest opening on the system) – the bigger the orifice the greater the initial mass flow and vice versa.

Now, let’s say we want a certain mass flow rate (x) coming out of the tank, whilst maintaining a constant pressure in the exiting gas. We can achieve the desired mass flow rate
by making an appropriately sized opening in the tank (I’ll call this opening O[i]) and adjusting the pressure using a pressure regulator. The issue here is that the pressure regulator could have a smaller opening (O[pr]) on its inside, ie O[i]>O[pr]. This would consequently reduce the mass flow rate coming from the tank.

It’s obvious that a pressure regulator can’t be used above a specific desired mass flow rate. What other devices could be used? A wider pressure regulator maybe?

I have included a diagram of a pressure regulator, which clearly shows the small opening inside.

enter image description here

2 Answers

I do that kind of thing regularly. My advice would be as follows:

  1. Work out what kind of pressure you need in the tank for the maximum flow rate
  2. Use a pressure regulator, as you mention in your question, rated to the pressure you worked out in #1.
  3. Make sure the supply pressure to the tank is sufficiently above the maximum pressure you worked out in #1 and within range of the pressure regulator chosen in #2.
  4. To control the mass flow rate, rather than using an orifice, use a mass flow controller on the outlet of the tank. This will ensure that you get the desired mass flow rate, while maintaining the correct pressure inside the tank. They can be expensive, but are well worth the money. I have had good experience with Bronkhorst ones.

Disclaimer: I do not work nor do I have any affiliation whatsoever with Bronkhorst, it's just from experience of using their products.

Answered by am304 on August 7, 2020

Your assessment of the situation is correct - the solution is of course to specify a pressure regulator with a large enough orifice that it does not cause you a problem.

Pressure regulators are specified with a Maximum Flow Rate, in the same way they are specified with Maximum Operating Pressure. You simply need to pick one that is suitable for your application.

Screenshot of RS Pressure Regulators

Answered by Jonathan R Swift on August 7, 2020

Add your own answers!

Related Questions

Meshing Error near Leading and Trailing edges

0  Asked on February 13, 2021 by shivam-goswami

     

Sutherland’s law for other gasses

0  Asked on February 13, 2021 by diesel

   

Is Viscosity = Slope?

0  Asked on February 10, 2021

       

Eccentricity for staggered 2×4 wal

2  Asked on February 10, 2021 by user2817017

     

How do cracks form on a ship’s hull?

2  Asked on February 8, 2021 by pyb

 

Why are there no mufflers for water plumbing?

0  Asked on February 8, 2021 by metamorphic

   

Pipe Invert Elevation

1  Asked on February 7, 2021

   

Ask a Question

Get help from others!

© 2022 AnswerBun.com. All rights reserved. Sites we Love: PCI Database, MenuIva, UKBizDB, Menu Kuliner, Sharing RPP, SolveDir