Home Improvement Asked by Wig on December 13, 2020

I have an electrical issue. I have a garage that is about 150 ft from the main house. Electric has been fine since we’ve moved in 10 hrs ago but now there is very little power (enough to turn on led light on a 18 v battery charger) .

The power is supplied from the main breaker box in the house where I have a 60 amp breaker that feeds the 2 main lines to the breaker box in the garage listed. I’ve Installed a new breaker in both boxes and tested the power. I have 244 volt coming in to the lines at the house and only 1 of the lines have power at the garage one has 121V and the other has 5V.

I’ve switched the lines at the breaker in the house. (figuring it would switch which line had 121V and which one has 5 Vin it).

After switching at house side and going to the garage, I TESTED THE LINES AND THEY WERE THE SAME AS BEFORE I SWITCHED THE LINES !

I am out of ideas, any advice would be appreciated.

One Answer

Open hot in the garage feeder

What you are seeing points to a break, or open, in one of the hot wires going from the main panel to the garage. With the all-too-common setup of a directly buried cable, this isn't all that uncommon a failure mode. I'd first turn the breaker going to the garage off and undo and redo the terminations on both ends of the cable with an inch-pound torque wrench set as per the labeling on the devices. If retorquing the connections doesn't fix the issue, then I'd be suspecting a broken underground wire, say due to a rodent chewing it. An electrician might be able to locate the break with special tools, but otherwise, it requires replacing the feeder outright, preferably with individual wires in a buried conduit, which isn't as likely to get gnawed to bits.

Answered by ThreePhaseEel on December 13, 2020

Add your own answers!

Related Questions

Changing bulb in shower ceiling light fixture

1  Asked on January 30, 2021 by steve-butler

 

Is a ten guage solid copper wire safe to use for a range?

2  Asked on January 30, 2021 by john-young

     

Bike cable type drain stuck down

1  Asked on January 30, 2021

   

Home Water Pressure

4  Asked on January 30, 2021 by ron-a

   

3way wiring with timer AND a dimmer

1  Asked on January 30, 2021 by bbishop660

       

Connecting Sub Ground to Main

1  Asked on January 30, 2021

   

How to remove this light globe?

2  Asked on January 29, 2021 by michael-karas

   

Air conditioning thermostat wiring help

1  Asked on January 29, 2021 by jeff-s

 

Water Seeping Under Fiberglass Shower Drain

1  Asked on January 29, 2021 by lmat-reinstate-monica

         

Sewer backup through basement floor drain after heavy rain

1  Asked on January 29, 2021 by eli-iser

     

Nest thermostat heating way beyond set temperature

3  Asked on January 29, 2021 by user2363777

       

Am I allowed to surface mount a hardwire LED Driver

0  Asked on January 29, 2021 by grbonk

 

Gas fireplace turning itself off

3  Asked on January 29, 2021 by ginny

 

Ask a Question

Get help from others!

© 2022 AnswerBun.com. All rights reserved. Sites we Love: PCI Database, MenuIva, UKBizDB, Menu Kuliner, Sharing RPP